8 / 9 page Product # MCOTS-F-270-P-QT Phone 1-888-567-9596 Doc.# 005-0005521 Rev. H 10/20/16 Page 8 MCOTS-F-270-P-QT Current: 4A Mil-COTS MIL-STD-810G Qualification Testing MIL-STD-810G Test Method Description Fungus 508.6 Table 508.6-I Altitude 500.5 - Procedure I Storage: 70,000 ft / 2 hr duration 500.5 - Procedure II Operating: 70,000 ft / 2 hr duration; Ambient Temperature Rapid Decompression 500.5 - Procedure III Storage: 8,000 ft to 40,000 ft Acceleration 513.6 - Procedure II Operating: 15 g Salt Fog 509.5 Storage High Temperature 501.5 - Procedure I Storage: 135 °C / 3 hrs 501.5 - Procedure II Operating: 100 °C / 3 hrs Low Temperature 502.5 - Procedure I Storage: -65 °C / 4 hrs 502.5 - Procedure II Operating: -55 °C / 3 hrs Temperature Shock 503.5 - Procedure I - C Storage: -65 °C to 135 °C; 12 cycles Rain 506.5 - Procedure I Wind Blown Rain Immersion 512.5 - Procedure I Non-Operating Humidity 507.5 - Procedure II Aggravated cycle @ 95% RH (Figure 507.5-7 aggravated temp - humidity cycle, 15 cycles) Random Vibration 514.6 - Procedure I 10 - 2000 Hz, PSD level of 1.5 g2/Hz (54.6 g rms), duration = 1 hr/axis Shock 516.6 - Procedure I 20 g peak, 11 ms, Functional Shock (Operating no load) (saw tooth) 516.6 - Procedure VI Bench Handling Shock Sinusoidal vibration 514.6 - Category 14 Rotary wing aircraft - helicopter, 4 hrs/axis, 20 g (sine sweep from 10 - 500 Hz) Sand and Dust 510.5 - Procedure I Blowing Dust 510.5 - Procedure II Blowing Sand EMI Military Standard 461 Compliance Matrix This table shows the MIL-STD-461 requirements/limits that will be met* by the stand-alone setups indicated below: Mil-Std-461 MIL-STD-461D/E/F Requirement Most Stringent Limit Listed Conducted Emissions CE101 CE102 Submarine Basic Curve Conducted Susceptibility CS101 CS106 CS114 CS115 CS116 Curve #2 461F Only Curve #5 Basic Waveform Imax = 10A Radiated Emissions RE101 Navy RE102† Submarine Fixed Wing Internal, >25 meters Nose to Tail Radiated Susceptibility RS101 RS103 Army Aircraft External * Susceptibility requirements/limits are considered to be met as long as transient deviations in the converter’s output voltage remain within ±10% of its initial value. † Met with metal screen shield covering the filter, converter, and resistive load. ‡ In almost every case the limit listed is the most stringent of the requirements. The one exception is CE03 - High Frequency Broadband Conducted Emissions, Converter with Passive Filter. In this case the filter and converter passed the A1 limit. The filter and converter pass the CE03 - Narrowband Conducted Emissions at the A5 limit level. MCOTS • MCOTS-F-28-P Filter • MCOTS-28-05S Converter • 120W Resistive load • Metal Chassis Plane • MCOTS-F-270-P Filter • MCOTS-270-05-QT Converter |
Số phần tương tự - CS115 |
|
Mô tả tương tự - CS115 |
|
|
Link URL |
Chính sách bảo mật |
ALLDATASHEET.VN |
Cho đến nay ALLDATASHEET có giúp ích cho doanh nghiệp của bạn hay không? [ DONATE ] |
Alldatasheet là | Quảng cáo | Liên lạc với chúng tôi | Chính sách bảo mật | Trao đổi link | Tìm kiếm theo nhà sản xuất All Rights Reserved©Alldatasheet.com |
Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
Family Site : ic2ic.com |
icmetro.com |