công cụ tìm kiếm bảng dữ liệu linh kiện điện tử |
|
TMP105-28 bảng dữ liệu(PDF) 1 Page - Tumbler Technologies + TRUMPower |
|
TMP105-28 bảng dữ liệu(HTML) 1 Page - Tumbler Technologies + TRUMPower |
1 / 2 page TMP105 Series 90-105 Watts Medical & ITE Power Adapters Tumbler Technologies + TRUMPower 3350 Scott Blvd., Building 13 • Santa Clara, California 95054, USA • 408-988-6616 • sales@trumpower.com • www.TRUMPower.com TRUMPower MODELS LIST . o N t c u d o r P ) 1 ( t u p t u O e g a t l o V m u m i x a M t n e r r u C k a e P ) 2 ( t n e r r u C m u m i x a M r e w o P 2 1 - 5 0 1 P M T V 2 1A 5 . 7A 5 1W 0 9 3 1 - 5 0 1 P M T V 3 1A 3 9 . 6A 8 . 3 1W 0 9 5 1 - 5 0 1 P M T V 6 1 ~ 4 1A 9 7 . 6A 8 5 . 3 1W 5 9 8 1 - 5 0 1 P M T V 9 1 ~ 8 1A 4 8 . 5A 6 . 1 1W 5 0 1 0 2 - 5 0 1 P M T V 1 2 ~ 0 2A 5 2 . 5A 5 . 0 1W 5 0 1 4 2 - 5 0 1 P M T V 5 2 ~ 4 2A 8 3 . 4A 7 . 8W 5 0 1 8 2 - 5 0 1 P M T V 9 2 ~ 8 2A 5 7 . 3A 5 . 4W 5 0 1 0 3 - 5 0 1 P M T V 2 3 ~ 0 3A 5 . 3A 2 . 4W 5 0 1 6 3 - 5 0 1 P M T V 8 3 ~ 6 3A 2 9 . 2A 5 . 3W 5 0 1 8 4 - 5 0 1 P M T V 0 5 ~ 6 4A 9 2 . 2A 7 . 2W 5 0 1 INPUT SPECIFICATIONS Input Voltage Range ............ 90~264 VAC Input Frequency ................... 47~63Hz Input Current ........................ 1.4A rms @ 115 VAC 0.7A rms @ 230 VAC Inrush Current ..................... 80A @ 115 VAC or 120A @ 230 VAC, at 25°C cold start Soft Start ............................... Yes Earth Leakage Current ........ 200µA max. @ 264 VAC, 63Hz Touch Current ...................... 100µA max. @ 264 VAC, 63Hz OUTPUT SPECIFICATIONS Output Power Ratings .......... See table Minimum Load ...................... Not required Tolerance ............................. ±5% Ripple and Noise* ............... 1% peak to peak max. at full load Overvoltage Protection ........ Set at 115-140% of its nominal output voltage Overcurrent Protection ........ Protected to short-circuit conditions Temperature Coefficient ..... ±0.04%/°C max. Transient Response ........... Max. excursion of 4% or better on all models, recovering to 1% of final value within 500 µs after a 25% step load change * Measured with 20MHz bandwidth at rated line voltage and output load ranges, with a 10µF tantalum capacitor in parallel with a 0.1µF ceramic capacitor in parallel across the output. GENERAL SPECIFICATIONS Power Factor ....................... 0.98 typical @ 115 VAC Efficiency ............................. 87% minimum at full load Hold-up Time ....................... 10 ms at 110 VAC Switching Frequency ........... 70~140KHz Operating Temperature ...... 0°C to +60°C Derating ............................... Derate from 100% at +40°C linearly to 50% at +60°C Storage Temperature .......... -40°C to +85°C Relative Humidity ................ 5°C to +95°C non-condensing Withstand Voltage ............... 5,656 VDC from input to output (4,000 VAC for Class II models) 2,121 VDC from input to ground 707 VDC from output to ground MTBF .................................... 150K hours minimum at full load, 25°C ambient, calculated per MIL-HDBK-217F STANDARDS & COMPLIANCES IEC/EN 61000-1-2 ............. EMC & Immunity Performance EN 55011, EN 55022 ........ Class B, conducted & radiated FCC, VCCI ......................... Class B, conducted & radiated EN 61000-3-2 .................... Harmonic distortion, Class A & D EN 61000-3-3 .................... Line flicker EN 61000-4-2 .................... ESD, ±8 KV air and ±6 KV contact EN 61000-4-3 .................... Radiated immunity, 3V/m EN 61000-4-4 .................... Fast transient/burst, ±2 KV EN 61000-4-5 .................... Surge, ±1 KV diff., ±2 KV com. EN 61000-4-6 .................... Conducted immunity, 3 Vrms EN 61000-4-8 .................... Magnetic field immunity, 3A/m EN 61000-4-11 .................. Voltage dip immunity, 30% reduction for 500ms, 60% reduction for 100ms, >95% reduction for 10ms Safety Standards ............... IEC/EN/UL 60601-1 (3rd Ed.), ANSI/AAMI ES 60601-1 (1st Ed.), CSA C22.2 No. 60601-1 (2nd Ed.), IEC/EN 60950-1 (2nd Ed.) Agency Approvals .............. UL, cUL, TUV, CE, CB Other Compliances .......... RoHS, CEC & Energy Star Level V FEATURES • 90~264 VAC Input, Soft Start • 0.98 Power Factor • 87% to 91% Efficiency • High Peak Power • Low Safety Ground Leakage Current • Class I & Class II Models Available • Compliant with CEC & Energy Star Level V Notes: 1) The listed P/N's are for Class I models equipped with IEC 320/C14 AC inlet. Add suffix "C2" to order Class II models equipped with IEC 320/C18 AC inlet. When ordering 14-50V output units, specify the requested voltage, e.g. use P/N TMP105-18.5-C2 to order 18.5V Class II model. 2) The peak current is for 10 seconds maximum with the average power not over the maximum power. |
Số phần tương tự - TMP105-28 |
|
Mô tả tương tự - TMP105-28 |
|
|
Link URL |
Chính sách bảo mật |
ALLDATASHEET.VN |
Cho đến nay ALLDATASHEET có giúp ích cho doanh nghiệp của bạn hay không? [ DONATE ] |
Alldatasheet là | Quảng cáo | Liên lạc với chúng tôi | Chính sách bảo mật | Trao đổi link | Tìm kiếm theo nhà sản xuất All Rights Reserved©Alldatasheet.com |
Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
Family Site : ic2ic.com |
icmetro.com |