công cụ tìm kiếm bảng dữ liệu linh kiện điện tử |
|
DM-301 bảng dữ liệu(PDF) 2 Page - List of Unclassifed Manufacturers |
|
DM-301 bảng dữ liệu(HTML) 2 Page - List of Unclassifed Manufacturers |
2 / 16 page 2 THERMOCOUPLE & RESISTANCE THERMOMETER SENSORS & PROBES CONTENTS Mineral Insulated, Flexible Sheath Thermocouples . . . . 3 Welded Tip, Fine Wire Thermocouples . . . . . . . . . . . . . . . . . 5 Thermocouples for specific Applications including Surface Air & Plastics Machinery Sensors . . . . . . . . . . . . . 6 Hand Held Thermocouple Probes . . . . . . . . . . . . . . . . . . . . . . 7 Furnace Thermocouples. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 Mineral Insulated, Flexible Sheath Platinum Resistance Thermometers. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 Fabricated, Rigid Sheath Platinum Resistance Thermometers. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 Platinum Resistance Thermometers for specific Applications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 Hand Held Platinum Resistance Thermometers . . . . . . 10 Platinum Resistance Thermometer Elements (Sensing Resistors) . . . . . . . . . . . . . . . . . . . . . . . . . . 10 Custom Sensors. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12 Probe Certification. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12 Installation Fittings for Temperature Sensors. . . . . . . . . 13 Head Mounting Temperature Transmitters . . . . . . . . . . . 13 Other Labfacility Products. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15 Choosing the sensor type: Thermocouples are less expensive than PRT sensors, more versatile, less accurate, more rugged, more sensitive, have a wider operating range, are tip sensitive and can be smaller. Extension cabling is more expensive. Various calibrations are available for different applications. PRT assemblies are much more accurate and stable, permit greater resolution of measurement but over a more limited range, are stem sensitive, larger and more expensive. Extension cabling is inexpensive copper wire. Remember the type of sensor chosen must suit the associated instrumentation. q Thermocouple & platinum resistance thermometers in a wide range of configurations & dimensions q Ranges from -200°C to 1700°C q Mineral insulated, flexible and fabricated, rigid probes q Fine wire thermocouples q Hand held probes q Plastics, surface & air sensors q Furnace thermocouples q Calibrated sensors q General purpose and application specific designs q Installation fittings q Head mounting temperature transmitters q Pt100 & Pt1000 detectors q ISO 9001 registered q Full compliance with IEC specifications q Thermocouple calibration types J,K,T,N,E,R & S available + – + – + – + – + – + – + – + – + – + – + – + – + – + – + – + – + – + – + – + – + – + – + – + – + – + – COLOUR CODES THERMOCOUPLE CONNECTORS, EXTENSION AND COMPENSATING WIRES AND CABLES INSULATION COLOUR CODES Extension & Compensating Leads CABLE CODE NICKEL CHROMIUM/CONSTANTAN EX E (Nickel Chromium/Copper Nickel, Chromel/Constantan, T1/Advance, NiCr/Constantan) J IRON*/CONSTANTAN JX (Iron/Copper Nickel, Fe/Konst Iron/Advance, Fe/Constantan I/C) K NICKEL CHROMIUM/NICKEL KX ALUMINIUM* (NC/NA, Chromel/Alumel, C/A, T1/T2, NiCr/Ni, NiCr/NiAL) N NICROSIL/NISIL NX NC T COPPER/CONSTANTAN TX (Copper/Copper Nickel, Cu/Con, Copper/Advance) Vx COPPER/CONSTANTAN KCB (LOW NICKEL) (Cu/Constantan) Compensating for K (Cu/Constantan) U COPPER/COPPER NICKEL RCA Compensating for Platinum 10% or 13% Rhodium/Platinum (Codes S & R respectively) (Copper/Cupronic SCA Cu/CuNi, Copper/No. 11 Alloy) * Magnetic, ( ) Alternative & Trade Name FOR THERMOCOUPLE CONNECTORS body colours are similar to outer sheath colours FOR THERMOCOUPLE CONNECTORS body colours are similar to outer sheath colours IEC584-3: 1989 BS4937. Part 30. 1993 The British Standard Colour Code for Thermocouple Cables, BS1843: 1952 is superseded by BS4937 PART 30 1993 (=IEC 584-3 1989) Additional identification as to whether a thermocouple cable type is extension or compensating is indicated in the example which follows; however, please note that a letter A or B after the C for Compensating refers to the Cable Temperature Range in accordance with the table of Tolerance Values set out with this standard. K – X – 1 = K EXTENSION CLASS 1 K – CA – 2 = K COMPENSATION CLASS 2 www.labfacility.co.uk Type J Type K Ty pe T Type N Type E Ty pe R Ty pe S All technical information published in this brochure is for guidance and not necessarily definitive. All thermocouple items comply with IEC 584 colour codes, cable and thermoelement tolerances unless otherwise stated. All platinum resistance thermometer items comply with IEC 751 tolerance and termination colour codes. All dimensions stated are nominal. Product availability & specifications may be subject to change. E & OE To receive our regular email newsletter, please register your details on our website FORMER STANDARD TYPE CONDUCTORS +/- BRITISH AMERICAN GERMAN BS1843: 1952 ANSI/MC 96.1 DIN 43713 / 43714 |
Số phần tương tự - DM-301 |
|
Mô tả tương tự - DM-301 |
|
|
Link URL |
Chính sách bảo mật |
ALLDATASHEET.VN |
Cho đến nay ALLDATASHEET có giúp ích cho doanh nghiệp của bạn hay không? [ DONATE ] |
Alldatasheet là | Quảng cáo | Liên lạc với chúng tôi | Chính sách bảo mật | Trao đổi link | Tìm kiếm theo nhà sản xuất All Rights Reserved©Alldatasheet.com |
Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
Family Site : ic2ic.com |
icmetro.com |