công cụ tìm kiếm bảng dữ liệu linh kiện điện tử |
|
MCZ33999EK bảng dữ liệu(PDF) 5 Page - Freescale Semiconductor, Inc |
|
MCZ33999EK bảng dữ liệu(HTML) 5 Page - Freescale Semiconductor, Inc |
5 / 21 page Analog Integrated Circuit Device Data Freescale Semiconductor 5 33999 ELECTRICAL CHARACTERISTICS STATIC ELECTRICAL CHARACTERISTICS STATIC ELECTRICAL CHARACTERISTICS Table 3. Static Electrical Characteristics Characteristics noted under conditions 3.1 V SOPWR 5.5 V, 5.0 V VPWR 18 V, -40°C TC 125°C unless otherwise noted. Typical values noted reflect the approximate parameter means at VPWR = 13 V, TA = 25°C under nominal conditions unless otherwise noted. Characteristic Symbol Min Typ Max Unit POWER INPUT Supply Voltage Range Fully Operational VPWR(FO) 5.0 – 27 V Supply Current All Outputs ON, IOUT = 0.3 A IPWR(ON) – 4.0 8.0 mA Sleep State Supply Current at RST 0.2 SOPWR and/or SOPWR 0.5 V IPWR(SS) – 1.0 10 A Overvoltage Shutdown VOV 27.5 31.5 35 V Overvoltage Shutdown Hysteresis VOV (HYS) 0.6 1.4 2.3 V VPWR Undervoltage Shutdown VPWR(UV) – 3.2 4.0 V SPI Interface Logic Supply Voltage SOPWR 3.1 – 5.5 V SPI Interface Logic Supply Current (RST Pin High) ISOPWR(RSTH) 100 – 500 A SPI Interface Logic Supply Current (RST Pin Low) ISOPWR(RSTL) -10 – 10 A SPI Interface Logic Supply Undervoltage Lockout Threshold SOPWR(UNVOL) 1.5 2.5 3.0 V POWER OUTPUT Drain-to-Source ON Resistance (IOUT = 0.35 A, VPWR = 13 V) TJ = 125C TJ = 25C TJ = -40C RDS(ON) – – – 0.75 0.55 0.45 1.1 – – Output Self-Limiting Current Outputs Programmed ON IOUT(LIM) 0.9 1.2 2.5 A Output Fault Detect Threshold (10) Outputs Programmed OFF VOUTTH(F) 2.5 3.0 3.5 V Output Off Open Load Detect Current (11) Outputs Programmed OFF (VPWR = 5.0 V, 13 V, 18 V) IOCO 25 50 100 A Output Clamp Voltage 2.0 mA IOUT 200 mA VCL 45 50 55 V Output Leakage Current SOPWR 2.0 V IOUT(LKG) -10 2.0 10 A Overtemperature Shutdown (Outputs OFF) (12) TLIM 155 165 180 C Overtemperature Shutdown Hysteresis (12) TLIM(HYS) 5.0 10 20 C Notes 10. Output Fault Detect Thresholds with outputs programmed OFF. Output Fault Detect Thresholds are the same for output open and shorts. 11. Output OFF Open Load Detect Current is the current required to flow through the load for the purpose of detecting the existence of an open load condition when the specific output is commanded to be OFF. 12. This parameter is guaranteed by design but is not production tested. |
Số phần tương tự - MCZ33999EK |
|
Mô tả tương tự - MCZ33999EK |
|
|
Link URL |
Chính sách bảo mật |
ALLDATASHEET.VN |
Cho đến nay ALLDATASHEET có giúp ích cho doanh nghiệp của bạn hay không? [ DONATE ] |
Alldatasheet là | Quảng cáo | Liên lạc với chúng tôi | Chính sách bảo mật | Trao đổi link | Tìm kiếm theo nhà sản xuất All Rights Reserved©Alldatasheet.com |
Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
Family Site : ic2ic.com |