8 / 12 page REV. 0 ADM1020 –8– Table IV. Configuration Register Bit Assignments Power-On Bit Name Function Default 7 MASK1 0 = ALERT Enabled 0 1 = ALERT Masked 6 RUN/STOP 0 = Run; 1 = Standby 0 5–0 Reserved 0 Conversion Rate Register The lowest three bits of this register are used to program the conversion rate by dividing the ADC clock by 1, 2, 4, 8, 16, 32, 64 or 128, to give conversion times from 125 ms (code 07h) to 16 seconds (code 00h). This register can be written to and read back over the SMBus. The higher five bits of this register are unused and must be set to zero. Use of slower conversion times greatly reduces the device power consumption, as shown in Table V. Table V. Conversion Rate Register Codes Average Supply Current Data Conversion/Sec A Typ at VCC = 3.3 V 00h 0.0625 42 01h 0.125 42 02h 0.25 42 03h 0.5 48 04h 1 60 05h 2 82 06h 4 118 07h 8 170 08h to FFh Reserved Limit Registers The ADM1020 has four Limit Registers to store local and re- mote, high and low temperature limits. These registers can be written to and read back, over the SMBus. The high limit regis- ters perform a > comparison while the low limit registers per- form a < comparison. For example, if the high limit register is programmed with 80 °C, then measuring 81°C will result in an alarm condition. One-Shot Register The One-Shot Register is used to initiate a single conversion and comparison cycle when the ADM1020 is in standby mode, after which the device returns to standby. This is not a data register as such and it is the write operation that causes the one- shot conversion. The data written to this address is irrelevant and is not stored. SERIAL BUS INTERFACE Control of the ADM1020 is carried out via the serial bus. The ADM1020 is connected to this bus as a slave device, under the control of a master device, e.g., the PIIX4 ADDRESS PIN In general, every SMBus device has a 7-bit device address (except for some devices that have extended, 10-bit addresses). When the master device sends a device address over the bus, the slave device with that address will respond. The ADM1020 has an address select pin, ADD to allow selection of the device ad- dress, so that more than one ADM1020 can be used on the same bus, and/or to avoid conflict with other devices. Although only one address pins is provided, it is a three-level input, and can be grounded, left unconnected, or tied to VDD, so that a total of three different addresses are possible, as shown in Table VI. It should be noted that the state of the address pin is only sampled at power-up, so changing it after power-up will have no effect. Table VI. Device Addresses ADD Device Address 0 1001 100 NC 1001 101 1 1001 110 NOTE: ADD is sampled at power-up only. The serial bus protocol operates as follows: 1. The master initiates data transfer by establishing a START condition, defined as a high-to-low transition on the serial data line SDATA, while the serial clock line SCLK remains high. This indicates that an address/data stream will follow. All slave peripherals connected to the serial bus respond to the START condition, and shift in the next eight bits, con- sisting of a 7-bit address (MSB first) plus a R/ W bit, which determines the direction of the data transfer, i.e., whether data will be written to or read from the slave device. The peripheral whose address corresponds to the transmitted address responds by pulling the data line low during the low period before the ninth clock pulse, known as the Acknowl- edge Bit. All other devices on the bus now remain idle while the selected device waits for data to be read from or written to it. If the R/ W bit is a 0, the master will write to the slave device. If the R/ W bit is a 1, the master will read from the slave device. 2. Data is sent over the serial bus in sequences of nine clock pulses, eight bits of data followed by an Acknowledge Bit from the slave device. Transitions on the data line must occur during the low period of the clock signal and remain stable during the high period, as a low-to-high transition when the clock is high may be interpreted as a STOP signal. The num- ber of data bytes that can be transmitted over the serial bus in a single READ or WRITE operation is limited only by what the master and slave devices can handle. 3. When all data bytes have been read or written, stop condi- tions are established. In WRITE mode, the master will pull the data line high during the 10th clock pulse to assert a STOP condition. In READ mode, the master device will override the acknowledge bit by pulling the data line high during the low period before the 9th clock pulse. This is known as no acknowledge. The master will then take the data line low during the low period before the 10th clock pulse, then high during the 10th clock pulse to assert a STOP condition. Any number of bytes of data may be transferred over the serial bus in one operation, but it is not possible to mix read and write in one operation, because the type of operation is determined at the beginning and cannot subsequently be changed without starting a new operation. |
Số phần tương tự - ADM1020AR-REEL |
|
Mô tả tương tự - ADM1020AR-REEL |
|
|
Link URL |
Chính sách bảo mật |
ALLDATASHEET.VN |
Cho đến nay ALLDATASHEET có giúp ích cho doanh nghiệp của bạn hay không? [ DONATE ] |
Alldatasheet là | Quảng cáo | Liên lạc với chúng tôi | Chính sách bảo mật | Trao đổi link | Tìm kiếm theo nhà sản xuất All Rights Reserved©Alldatasheet.com |
Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
Family Site : ic2ic.com |
icmetro.com |