công cụ tìm kiếm bảng dữ liệu linh kiện điện tử |
|
ADC413 bảng dữ liệu(PDF) 2 Page - MPS Industries, Inc. |
|
ADC413 bảng dữ liệu(HTML) 2 Page - MPS Industries, Inc. |
2 / 2 page ADC400 SERIES Min. Max. Units Parameter Min. Typ. Max. Units 5VDC Input Models -0.7 9 VDC Isolation Voltage 6000 --- --- VDC 12VDC Input Models -0.7 18 VDC Isolation Resistance 10 --- --- GΩ --- 260 °C Isolation Capacitance --- 15 20 pF --- 650 mW Switching Frequency 50 80 100 kHz Parameter Conditions Min. Max. Units Parameter Min. Typ. Max. Units Operating Temperature Ambient -25 70 °C Line Regulation --- ±1.2 ±1.5 % Operating Temperature Case -25 90 °C Load Regulation % Storage Temperature -40 125 °C Ripple & Noise --- 100 150 mV P-P Humidity --- 95 % Short Circuit Cooling Units uF 2463 208th Street, Ste. 205 http://www.mpsind.com Torrance, CA 90501 E-mail: sales@mpsind.com Tel: (310) 533-1455 Fax: (310) 533-1853 --- MHrs Environmental Characteristics Free-Air Convection Output Characteristics See Selection Guide 0.5 Second Max. 1W, Ultra-High Isolation SIP, Single & Dual Output DC/DC Converters Absolute Maximum Ratings Parameter Input Surge Voltage (1000mS) Conditions 60 Seconds 500VDC General Characteristics Lead Temperature (1.5mm from case for 10sec.) Internal Power Dissipation Exceeding the unit absolute maximum ratings could cause damage. These are not continuous operating ratings. --- 100kHz, 1V 20MHz BW MTBF 2 Maximum Capacitive Load MIL-HDBK-217F @25°C Ground Benign Conditions For Vin Change of 1% Io = 20% to 100% Models by Output Voltage (Each Output on Duals) Notes: 1. Specifications typical at Ta=+25°C, resistive load, nominal input voltage, rated output current unless otherwise noted. 2. These power converters require a minimum output load to maintain specified regulation. 3. Operation under no-load conditions will not damage these modules; however, they may not meet all specifications listed. 4. All DC/DC converters should be externally fused at the front end for protection. 5. Other input and output voltage may be available, please contact factory. 6. All specifications subject to change without notice. 7. For detailed data sheet, please visit our website. Derating Curve Singles Duals 680 220 ¡ã ] Ambient Temperature 0 20 40 60 80 100 -25 50 60 80 100 110 90 70 400LFM 200LFM 100LFM Natural convection |
Số phần tương tự - ADC413 |
|
Mô tả tương tự - ADC413 |
|
|
Link URL |
Chính sách bảo mật |
ALLDATASHEET.VN |
Cho đến nay ALLDATASHEET có giúp ích cho doanh nghiệp của bạn hay không? [ DONATE ] |
Alldatasheet là | Quảng cáo | Liên lạc với chúng tôi | Chính sách bảo mật | Trao đổi link | Tìm kiếm theo nhà sản xuất All Rights Reserved©Alldatasheet.com |
Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
Family Site : ic2ic.com |
icmetro.com |