công cụ tìm kiếm bảng dữ liệu linh kiện điện tử |
|
ADE8052Z-EMUL1 bảng dữ liệu(PDF) 6 Page - Analog Devices |
|
ADE8052Z-EMUL1 bảng dữ liệu(HTML) 6 Page - Analog Devices |
6 / 156 page ADE5166/ADE5169/ADE5566/ADE5569 Rev. B | Page 6 of 156 SPECIFICATIONS VDD = 3.3 V ± 5%, AGND = DGND = 0 V, on-chip reference XTALx = 32.768 kHz, TMIN to TMAX = −40°C to +85°C, unless otherwise noted. ENERGY METERING Table 2. Parameter Min Typ Max Unit Test Conditions/Comments MEASUREMENT ACCURACY1 Phase Error Between Channels PF = 0.8 Capacitive ±0.05 Degrees Phase lead: 37° PF = 0.5 Inductive ±0.05 Degrees Phase lag: 60° Active Energy Measurement Error2 0.1 % of reading Over a dynamic range of 1000 to 1 at 25°C AC Power Supply Rejection2 VDD = 3.3 V + 100 mV rms/120 Hz Output Frequency Variation 0.01 % IPx = VP = ±100 mV rms DC Power Supply Rejection2 VDD = 3.3 V ± 117 mV dc Output Frequency Variation 0.01 % Active Energy Measurement Bandwidth1 8 kHz Reactive Energy Measurement Error2 0.5 % of reading Over a dynamic range of 1000 to 1 at 25°C Vrms Measurement Error2 0.5 % of reading Over a dynamic range of 100 to 1 at 25°C Vrms Measurement Bandwidth1 3.9 kHz Irms Measurement Error2 0.5 % of reading Over a dynamic range of 500 to 1 at 25°C Irms Measurement Bandwidth1 3.9 kHz ANALOG INPUTS Maximum Signal Levels ±500 mV peak VP − VN differential input ADE5166/ADE5169 ±500 mV peak IPA − IN and IPB − IN differential inputs ADE5566/ADE5569 ±500 mV peak IP − IN Input Impedance (DC) 770 kΩ ADC Offset Error2 ±10 mV PGA1 = PGA2 = 1 ±1 mV PGA1 = 16 Gain Error2 Current Channel ±3 % IPA = IPB = 0.5 V dc or IP = 0.5 V dc Voltage Channel ±3 % VP − VN = 0.5 V dc Gain Error Match ±0.2 % CF1 AND CF2 PULSE OUTPUT Maximum Output Frequency 21.6 kHz VP − VN = 500 mV peak; IPA − IN = 500 mV for the ADE5166/ADE5169; IP − IN = 500 mV for the ADE5566/ADE5569 Duty Cycle 50 % If the CF1 or CF2 frequency > 5.55 Hz Active High Pulse Width 90 ms If the CF1 or CF2 frequency < 5.55 Hz FAULT DETECTION3 Fault Detection Threshold Inactive Input ≠ Active Input 6.25 % of active IPA or IPB active Input Swap Threshold Inactive Input > Active Input 6.25 % of active IPA or IPB active Accuracy Fault Mode Operation IPA Active, IPB = AGND 0.1 % of reading Over a dynamic range of 500 to 1 IPB Active, IPA = AGND 0.1 % of reading Over a dynamic range of 500 to 1 Fault Detection Delay 3 Seconds Swap Delay 3 Seconds 1 These specifications are not production tested but are guaranteed by design and/or characterization data on production release. 2 See the Terminology section for definition. 3 Available only in the ADE5166/ADE5169. |
Số phần tương tự - ADE8052Z-EMUL1 |
|
Mô tả tương tự - ADE8052Z-EMUL1 |
|
|
Link URL |
Chính sách bảo mật |
ALLDATASHEET.VN |
Cho đến nay ALLDATASHEET có giúp ích cho doanh nghiệp của bạn hay không? [ DONATE ] |
Alldatasheet là | Quảng cáo | Liên lạc với chúng tôi | Chính sách bảo mật | Trao đổi link | Tìm kiếm theo nhà sản xuất All Rights Reserved©Alldatasheet.com |
Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
Family Site : ic2ic.com |
icmetro.com |